Monitoring the Tour Perret at Grenoble, France (RESIF-SISMOB)
RESIF - Réseau Sismologique et géodésique Français
2023
Seismic network
Seismic structural
Health
Monitoring
Culturate heritage building
Reinforced concrete
RESIF Information System
RESIF Data Centre
Sismo-Help@Resif.Fr
Université Grenoble Alpes, Grenoble, France (UGA)
Institut Des Sciences De La Terre, Grenoble, France (ISTerre)
Université Grenoble Alpes, Grenoble, France (UGA)
RISE-EU
2021-04-27/2022-12-31
2023-12-31
2023
http://www.resif.fr
2 stations, 17Go (miniseed format)
Miniseed data
stationXML metadata
Within the framework of the preservation of cultural heritage in reinforced concrete, the URBASISMonitoring-Perret experiment aims to monitor the Perret Tower (built in 1924) in Grenoble, the first high-rise building (about 80m) in reinforced concrete. Since its construction, many pathologies linked to its damage have appeared. A rehabilitation project has been launched and in this framework, we wish to develop a research program on multi-instrument operational modal analysis (DAS, velocimeters, inclinometers...) and to search for the signature of the damage using SHM techniques.
France
5.735410
5.735410
45.184960
45.184960